Sterilisation and patient safety
Maintaining the highest standards of sterilisation and hygiene to ensure every patient’s safety and well-being.
Sterilization and Patient Safety
Just as it is important to keep your smile clean, we believe that it is extremely vital to keep our office clean for a safe and confident dental experience. Our entire dental team is committed to follow rigorous standards of safety and cleanliness. We use the latest advancements in sterilization techniques to keep all of our equipment, instruments, and surfaces clean and safe of bacteria, germs, and any microorganisms normally associated with a dental office.
We follow sterilization guidelines approved by the American Dental Association.
Ultrasonic Cleaner
Used instruments are cleaned using an Ultrasonic Cleaner
The ultrasonic activity — also known as cavitation — combined with detergent solutions, removes blood, saliva, and other debris from instruments.
Disposable autoclavable pouches
The cleaned instruments are then packed in disposable pouches and autoclaved.
All sterile/autoclaved instruments are stored well in disposable pouches which are seal opened at the time of use only.
Vacuum (Type B) Autoclave
The preferred method for sterilization of dental instruments is by autoclaving – using saturated steam under pressure at the highest temperature compatible with the instrument. Ideally instruments should be sterilized at 134 degrees for three minutes.
Steam sterilization requires direct contact between the saturated steam and every surface of the instrument to destroy all microorganisms. As this direct contact can be prevented by the presence of air in the chamber a vacuum must be present to remove the air and enable steam penetration.
The triple pulse, pre-vacuum phase of a “Type B vacuum autoclave” utilizes a powerful vacuum pump to forcibly remove all the residual air from within the chamber and load, enabling steam to circulate freely and rapidly, and allowing good penetration of the steam into the load, thus ensuring fully effective sterilization.
All instruments with lumens or cavities and porous loads (e.g. swabs or dressings) are sterilized in a vacuum autoclave.
An advantage of pouching all instruments is that they remain sterile for up to 6 months until you use them.
Disposables
Operating instruments like injecting needles, syringes, surgical blades are disposable & discarded after single use.
Gloves, mouth masks, suction tips, all of which are disposable are discarded after single use in front of the patient to assure our patients that we ensure complete transparency in our sterilization, disinfection & hygiene protocol.
All surfaces in the treatment rooms are cleaned and disinfected after each procedure.
The doctors as well as the staff follow strict measures of sterilization to avoid cross contamination.
Lead Aprons and Thyroid Collars
Ionizing radiation, can present a significant health hazard by causing microscopic damage to living tissue. We are extremely concerned about the safety of our patients and staff and so lead aprons and thyroid collars are always used when taking x-rays that act as a radiation shield.
Water Distiller
We use distilled water for our autoclaves, dental chair lines and dental hand pieces which are used on teeth intraorally. Distilled water is an important key in preventing bacteria and biofilm build up in water lines which is considered as a fundamental patient safety issue by The American Dental Association.